HPLC Column, RP C4 Butyl, Wide Pore, 5um, 2.1mm ID x 150mm Length, 300A. Cogent Brand. 1 EA.
Additional Information:
Cogent RP C4™ Wide Pore is a reversed-phase HPLC stationary phase designed for the separation of proteins, peptides, enzymes, and other large hydrophobic or neutral compounds. Manufactured using a four-carbon butyl ligand bonded to ultra-high purity silica and fully double end capped, this 300 Å wide pore stationary phase provides improved accessibility for larger biomolecules while maintaining the reduced hydrophobic retention characteristics of C4 chemistry. The wide pore architecture makes this phase particularly useful for bioanalytical and biopharmaceutical applications where larger molecules require efficient interaction with the bonded surface.
68504-15P-2-3M is an HPLC column packed with 5 µm RP C4™ Wide Pore particles featuring a 300 Å pore size in a 2.1 mm ID x 150 mm format. This narrow-bore configuration combines high chromatographic resolution with reduced solvent consumption and excellent compatibility with LC-MS instrumentation. The 150 mm length provides increased peak capacity and resolving power compared to shorter column formats, while the 300 Å pore structure improves accessibility and mass transfer for proteins, peptides, enzymes, and other large biomolecules. Typical operating flow rates are approximately 0.2–0.3 mL/min. Standard HPLC systems used with 2.1 mm ID columns must be capable of precise and reproducible low-flow operation.
This column is particularly useful for bioanalytical workflows involving proteins, peptides, enzymes, and other high molecular weight compounds. Compared to more hydrophobic C8 and C18 phases, the C4 bonded phase generally provides lower retention, which can improve recovery and peak shape for larger analytes. The 2.1 mm ID format is especially popular for LC-MS applications due to reduced solvent consumption, enhanced sensitivity, and efficient analyte transfer to the mass spectrometer.
Key Benefits
RP C4™ Wide Pore stationary phase
USP L26 equivalent chemistry
Butyl (C4) bonded phase
Fully double end capped
Ultra-high purity silica support
300 Å wide pore design
Optimized for proteins and peptides
Lower hydrophobic retention than C8 phases
5 µm particle size
Excellent for LC-MS bioanalysis
Typical Applications
Protein analysis
Peptide analysis
Enzyme analysis
Bioanalytical methods
LC-MS methods
Biomolecule characterization
Pharmaceutical analysis
Biopharmaceutical analysis
Reversed-phase HPLC
Method development
Specifications
Product Type: HPLC Column
Stationary Phase: RP C4™ Wide Pore
USP Classification: L26
Chromatography Mode: Reversed Phase
Bonded Phase: Butyl (C4)
Endcapping: Fully Double End Capped
Particle Size: 5 µm
Pore Size: 300 Å
Column Dimensions: 2.1 mm ID x 150 mm
Length: 150 mm
Typical Flow Rate: 0.2–0.3 mL/min
Brand: Cogent
Important Notes
Designed for proteins, peptides, enzymes, and other large biomolecules
300 Å wide pores improve accessibility for larger analytes
Provides less retention than C8 and C18 stationary phases
Suitable for reversed-phase HPLC and LC-MS applications
The 2.1 mm ID format is ideal for reduced solvent consumption and LC-MS compatibility
Standard HPLC systems must be capable of reliable operation at approximately 0.2–0.3 mL/min
Detector flow cells should be optimized for low-volume, narrow-bore chromatography
The 150 mm length provides greater resolution and peak capacity than shorter column formats
5 µm particles provide low backpressure and robust operation
Frequently used for bioanalytical and biopharmaceutical applications